Uji Sterilitas Linen Basah yang telah Disterilkan dengan Steam Sterilizer

Milala, Alasen Sembiring (2017) Uji Sterilitas Linen Basah yang telah Disterilkan dengan Steam Sterilizer. In: Seminar Nasional Asosiasi Perguruan Tinggi Farmasi Indonesia (APTFI) II, 16-18 Nopember 2017, Banjarmasin.

[thumbnail of UJi Sterilitas Linen Basah_Abstrak_2017.pdf]
Preview
PDF
UJi Sterilitas Linen Basah_Abstrak_2017.pdf

Download (609kB) | Preview
[thumbnail of UJI STERILITAS LINEN BASAH.pdf]
Preview
PDF
UJI STERILITAS LINEN BASAH.pdf

Download (1MB) | Preview
[thumbnail of Brosur, daftar acara dan sertifikat.pdf]
Preview
PDF
Brosur, daftar acara dan sertifikat.pdf

Download (1MB) | Preview

Abstract

Linen is one of the health supplies needed by the hospital in large quantities. The availability of clean and sterile linen is one of the supporting facilities for the health of hospitalized patients. To obtain clean linen is done through several processes, including cleaning, disinfection, washing, drying, and sterilization. Linen sterilization was carried out by steam sterilizer at 134oC for 3 minutes, with the final result in wet conditions. In wet conditions the microbe is easy to grow, so it is necessary to do sterility testing. Therefore performed sterility test by direct inoculation method using cotton swab. Samples for the sterility test were taken on days 0, 1, 2, 3, 4 respectively. Each was taken 4 samples. Replicated 3 times to ensure the accuracy of the results. Sterility test, fertility test and LAFC effectiveness test was performed to avoid the occurrence of false positives. As control of the implementation of aseptic technique, sterility test of cotton swab and wetting fluid was performed. As a guarantee that the sterilization process is running well, validation of sterilization process using physical, chemical and biological indicators. Growth media used is Fluid Thyoglycollate Medium to detect the presence of bacteria and Soybean Casein Digest Medium to detect the fungus. The results showed that the linen with wet end results can be guaranteed for sterility during storage until day 0, since the growth of fungus occurs on day 1 and bacterial growth occurs on day 2 during storage.

Item Type: Conference or Workshop Item (Paper)
Uncontrolled Keywords: Wet linen, steam sterilizer, sterility test
Subjects: R Medicine > RS Pharmacy and materia medica
Divisions: Faculty of Pharmacy > Department of Pharmacy
Depositing User: Eko Setiawan 194014
Date Deposited: 20 Nov 2017 08:29
Last Modified: 20 Nov 2017 10:50
URI: http://repository.ubaya.ac.id/id/eprint/31187