Soesetijo, Sis and Mauludiyanto, Achmad and Hendrantoro, Gamantyo (2009) Rain Cell Size Determination using Granger Causality Test. In: 1st APTECS 2009, 22 Desember 2009, ITS Surabaya.
Preview  | 
            
              
PDF
 ssoesetijo_aptecs2009_lppm_its_en.pdf Download (219kB) | Preview  | 
          
Abstract
Site Diversity is one of techniques to compensate rain attenuation in milimeter-wave. However, to implement appropriate site diversity techniques have to involve base knowledge about rain cell dimension. In this paper, Vector AR (VAR) Model with Granger Causality Test is implemented to rainrate at 3 raingauge sites. Granger Causality test is used to check whether one site “granger-cause” to another site and vice versa. The result show that site C “granger-cause” to site B and site B “granger-cause” to site A. It mean that rain cell have < 1 km diamater
| Item Type: | Conference or Workshop Item (Paper) | 
|---|---|
| Uncontrolled Keywords: | Granger Causality Test, Vector AR | 
| Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering | 
| Divisions: | Faculty of Engineering > Department of Electrical Engineering | 
| Depositing User: | Sis Soesetijo 61133 | 
| Date Deposited: | 16 Jun 2012 03:13 | 
| Last Modified: | 16 Jun 2012 03:13 | 
| URI: | http://repository.ubaya.ac.id/id/eprint/615 | 